<LOGO>
FM Transmitter Measurement Report
Created: 2023-07-13 05-33-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.80 MHz 4/5, 52 dBuV NOSTALGI
Pilot RDS Phase Difference
7.0 kHz 3.9 kHz -32 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 71 kHz 16185 2,3664
Modulation Power
Limit Measuring Tolerance
8,0 dBr 1,0 dBr
MIN AVE MAX % above 9,0 dBr
4,1 dBr 5,27 dBr 5,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" F218 0 (No PTY) 1 0 1 2 5:33, 13.07.2023
RT
"NOSTALGIE : I Will Survive - HERMES HOUSE BAND "
AF EON
91.9, 99.7, 100.7, 101.2, 106.2, 106.3, 106.5, 106.8 MHz -
FM Scope Station: 106.80 MHz, signal: 4/5 (52 dBuV) Max at: 71 kHz MIN: 11 kHz % above 75 kHz: 2,3664 Acquired: 2023/07/13 5:32:42 Total samples: 16185 Equivalent time: 0:13:29 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,8 dBr MIN: 4,1 dBr AVE: 5,27 dBr % above 9,0 dBr: 0,0 Last value: 5,8 dBr (2023/07/13 5:32:41) Station: 106.80 MHz, signal: 4/5 (52 dBuV) 05:20 05:22 05:24 05:26 05:28 05:30 05:32 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality